L
O
A
D
I
N
G

Get a Free Quote

Our representative will contact you soon.
Email
Mobile
Name
Company Name
Message
0/1000

SF4091 Basic Structural Installation of the Panel Single-Sided Riveting Machine

Nov 25, 2026

image.png

Equipment Structural Configuration

image.png

Machine Installation

1. Machine Handling

When transporting the machine with a forklift, the forklift must have sufficient load capacity. The spacing between the two forks should match the width of the machine body underneath, and the forks must be long enough to extend beyond the machine body. During handling, ensure that the machine surface is not damaged and that the machine base is not bumped or otherwise damaged.

2. Machine Installation

2.1 Installation of the Machine Mechanical Structure

image.png

image.png

Level the machine longitudinally and transversely by adjusting the height of the foundation screws.

2.2 Machine Electrical Wiring and Grounding

Ensure that the workshop main power supply meets the machine's power requirements, and check that the main voltage matches the machine's operating voltage. The cross-sectional area of the cable shall be determined according to the machine's total capacity. For this machine model, a copper cable with a cross-sectional area of at least 4 mm² is recommended. The cable overcurrent protection device should be set to approximately 40 A. Ensure that the machine is reliably grounded. For machine safety grounding, determine the cable entry point according to the production layout, connect the cable to the machine's wiring terminals, and check the motor rotation direction.

image.png

image.png

Note: When wiring, the user must follow the requirements of the electrical schematic supplied with the machine. The machine's electrical system must be wired and maintained by a properly trained electrician.

2.3 Connection of Compressed Air to the Machine

Ensure that the workshop air supply meets the machine's requirements. Only an adequate air supply can ensure optimum machine performance. The compressed air supplied by the air source must be dry and free of water and must meet the following parameters required by the machine:

- Inner diameter of air supply pipe ≥ Φ6.5 mm

- Air pressure 0.5–0.8 MPa

- Air consumption 0.3 m³/min

Refer to the machine pneumatic schematic and the air-source treatment triple unit supplied with the machine (installed at the lower end of the infeed side of the machine body), and understand the principles and operation of the following pneumatic components.

2.3.1 Air Filter and Oil Mist Lubricator (see Figure 2-1)

image.png

(Figure 2-1)

This device uses cyclone blades to separate water and sintered steel-ball micropores to trap dust, providing dry and clean air throughout the pneumatic circuit. The separated water and dust can be clearly seen through the transparent glass cup. The user should determine the drainage interval according to the amount collected and open the valve beneath the cup to drain it.

Powered by compressed air, this device atomizes lubricating oil to lubricate the pneumatic components. The user can adjust the oil quantity by using the adjustment device to control the oil-drip rate.

2.3.2 Pressure-Reducing Valve and Pressure Gauge (see Figure 3-1)

image.png

(Figure 3-1)

The pressure-reducing valve and pressure gauge are connected together and connected to the air filter and oil mist lubricator. To adjust the pressure-reducing valve, first pull out the knob and rotate it until the output working pressure is approximately 0.4 MPa. After adjustment, promptly press the knob back in to reset it.

2.4 Machine Emergency Braking

image.png

In an emergency, press the “EM.STOP” button on the machine's electrical control panel or pull the emergency-stop cable,the machine will stop immediately and the fault indicator “EM.STOP” light will illuminate.

Note: Use the “EM.STOP” button only in an emergency. Frequent use of this button will cause it to fail prematurely!

2.5 Motor Protection

The control circuit is equipped with automatic motor overload protection.

image.png